GETTING READY TO PROGRAM
BTE HEARING AIDS:
BTE hearing aids are Quick Fit to a
50 dB flat hearing loss
Remove battery during programming
Lift programming port cover and
insert cable
Connect other end of the cable to the
HI-PRO box or NOAHlink
Program button, manual volume
control and automatic options are
deactivated during programming
GETTING READY TO PROGRAM
CUSTOM HEARING AIDS:
Custom hearing aids are Quick Fit if
an audiogram is supplied
Hearing aids with a manual volume
control must be turned to the ‘on’
position by turning the volume
control wheel
Remove battery door and insert
appropriate right or left cable
Connect other end of the cable to the
HI-PRO box or NOAHlink
Program button, manual volume
control and automatic options are
deactivated during programming
Element
Programming Guide
Ear HookDual Directional
Microphones
Program Button
Battery Door
Battery Door
Program Button
Dual Directional
Microphones
Volume Control
Volume Control
Microphone Protection
Programming Port Cover
Przeglądanie stron 0
1 2 3 4 5 6 ... 15 16

Podsumowanie treści

Strona 1 - Programming Guide

GETTING READY TO PROGRAMBTE HEARING AIDS: • BTE hearing aids are Quick Fit to a 50 dB flat hearing loss • Remove battery during programming • Lift pro

Strona 2

To change the order of the manual programs at any time during the fitting: 1. Click Fitting on the menu bar.2. Select Swap Programs.3.Click the desir

Strona 3 - Client Screen

Fitting AdviceScreenThe Fitting Advice screen fine tunes thehearing aid based on the clients’ comments,complaints and observations. The currentlyactiv

Strona 4 - Instruments Screen

Fine Tuning ScreenU:fit’s Fine Tuning screen modifies the hearingaid frequency response, MPO and Compressionratios. You may fine tune the hearing aid

Strona 5 - Pre-Fitting Screen

Element Programming GuideAutoPro2 / AutoMicControls ScreenThere are two controls to adjust howautoPro2 or autoMic responds to changes inthe environmen

Strona 6 - Fitting Screen

Data LoggingScreenAt the initial fitting, no data logginginformation will be available. When saving tothe hearing aid(s), data logging is activatedby

Strona 7 - Optimization

Element Programming GuideUnderstanding the Data Logging Information:The top of the data logging screen indicates:• Logging Start: The date the data lo

Strona 8 - Quick Tuning Screen

End Fitting ScreenTo configure the End Fitting screen:1. Use the controls to adjust the BeepFrequency and Beep Intensity, if required. 2.Check on or o

Strona 9 - Configure Screen

When you are ready to program Element™, certain sections on thescreen will remain constant during the fitting process. A briefdescription of these sec

Strona 10

Client ScreenThe client screen is only available in theStandalone version of U:fit. To enter a new client:1. Click Add New Client.2. Enter the client

Strona 11 - Element Programming Guide

Instruments ScreenOnce the client’s information and audiometricdata has been entered, the next step is toeither detect the hearing aid or simulate afi

Strona 12 - Fine Tuning Screen

To simulate a hearing aid fitting:1. Click Simulate or Simulate from the left navigation menu. 2. Select the desired Element shell style3. Click Right

Strona 13 - Controls Screen

To modify the default fitting formula and transducer settings:1. Click Options.2. Select Preferences.3.Select Fitting Preferences.RECD and REUGTo comp

Strona 14 - Data Logging

FeedbackOptimizationScreenAt the initial fitting, the first step is to run theFeedback Optimization test to activate thephase canceller. This test wil

Strona 15

Quick Tuning ScreenThe Quick Tuning screen is designed to address the first sound impression duringa fitting. The hearing aid’s global parameters,occl

Strona 16 - End Fitting Screen

Configure ScreenIn the Configure screen, you can review thesettings for all adaptive parameters andinput. These settings will automaticallydefault to